Pro-Line™ Remote Power Pack - 7,250 BTU - 1 HP - 2 Pumps - Air Cooled
Quantity
Total Cost: $0.00

The Micro Matic MMPP4305-PKG-R Pro-Line™ Remote Power Pack is designed for long-draw draft beer systems that circulate chilled glycol alongside beer lines to help maintain dispensing temperatures between the walk-in cooler and faucets.
Unlike a self-contained power pack, this remote (split-deck) model allows the air-cooled compressor to be located separately in an appropriately ventilated area while the glycol bath remains near the walk-in cooler.
The unit combines 7,250 BTU cooling capacity, a 1 HP air-cooled compressor, an 11.5-gallon glycol bath, and two glycol-recirculation pumps.
Pro-Line™ Remote Power Pack Features
- 7,250 BTU cooling capacity – Provides refrigeration capacity for an appropriately sized long-draw draft system.
- 1 HP air-cooled compressor – Forms part of the remote refrigeration system.
- Two rotary-vane recirculation pumps – Circulate glycol through the trunkline cooling system.
- 11.5-gallon insulated glycol bath – Holds the glycol mixture and includes insulation within the bath walls and floor.
- Bath-level sight glass – Allows the glycol level to be checked without removing the lid.
- Adjustable digital thermostat – Displays the glycol temperature and permits adjustments.
- Lift-off deck lid – Provides access for inspection and servicing.
- Remote/split-deck arrangement – Allows separate placement of the compressor and glycol bath according to manufacturer installation requirements.
Why Choose a Remote Glycol Power Pack?
The surrounding temperature and available ventilation can affect where a glycol power pack should be installed. A remote configuration allows the air-cooled compressor to be positioned separately from the glycol bath, which can remain near the walk-in cooler.
This can help when the area near the walk-in cooler has limited ventilation or is exposed to higher ambient temperatures.
Compressor placement, allowable separation distance, and refrigeration connections must follow the manufacturer's installation instructions. Do not assume that every indoor or outdoor location is suitable.
Electrical and Remote Installation Requirements
The MMPP4305-PKG-R is listed as a 208/230V remote power pack with a NEMA 6-20P plug.
The manufacturer recommends reviewing the electrical load and having a certified electrician perform electrical work. Check the current product specification sheet, equipment nameplate, and installation manual for electrical requirements, compressor placement, refrigeration connections, and service clearances.
Units manufactured before February 1, 2022, may have a different plug configuration. Verify the actual unit before planning electrical connections.
Comparing Pro-Line™ Glycol Power Packs
For a self-contained air-cooled alternative, compare the MMPP4305-PKG two-pump power pack. It shares the listed 7,250 BTU cooling capacity and 1 HP compressor but uses a self-contained configuration rather than a remote split-deck design.
For a water-cooled option, consider the MMPP4305-PKG-WC power pack.
These configurations have different ventilation, water, refrigeration, and installation requirements. Confirm the appropriate model through system sizing and current manufacturer documentation.
Glycol Preparation, Refrigerant, and Warranty
Follow the current Micro Matic installation manual for glycol preparation and bath maintenance. The manufacturer recommends distilled water for its specified glycol mixture. Confirm the approved proportions before preparing the solution.
For MMPP4305-series units manufactured after March 1, 2023, Micro Matic identifies R513a refrigerant. Check the supplied unit's production revision and nameplate before refrigeration servicing.
The manufacturer also provides warranty coverage for materials, workmanship, labor, and the compressor, subject to the applicable warranty terms.
Remote power packs are described by Micro Matic as made-to-order products. Confirm current availability and lead time before ordering.
Selecting the Right Glycol Power Pack
Choose a power pack based on the draft system's calculated cooling load, trunkline arrangement, circulation needs, available ventilation, and installation constraints.
Use the Micro Matic BTU Calculator to assess the system's cooling requirements, or browse the Power Packs category to compare additional configurations.